Search published articles


Showing 5 results for Plate

M Fatemi Motlagh, N Mansoori,
Volume 3, Issue 2 (10-2009)
Abstract

Abstract Background and objectives: Halo interference around antibiogram disc is one of the problems seen in Agar media. This study aimed at applying graded plate method to reduce this problem. Material and Methods: Forty-eight millimeter plates, before putting disc, were graded and the location of discs was determined. Instead of full disc, we used half-disc and then compared the haloe interference, based on clinical and Laboratory Standard Institute (CLSI), of Klebseila Pneumoniae in the presence of nine different antibiotics. Results: The tests performed on Klebseila Pneumoniae show that five antibiotics such as Enrofloxacin (24mm), Flumequine (12mm), Furazolidone (22mm), ampicillin (22mm) and Florfenicle (22mm) cause non-growth haloes while none of them has interference haloe when we use the news method. Conclusion: According to results, the graded plate not only has negative effect on Antibiogram results but also is careful and decrease the interference produced by previous methods and its efficacy is increased up to %17.64 when we use 84 diametered Plate. Keywords: Antibiotic, Disc diffusion test, Dispensing disc, Non-growth haloes, Non-growth haloes interference, Plate
M Fatemi Motlagh, H Varham, N Mansori,
Volume 4, Issue 2 (10-2010)
Abstract

Abstract Background and objectives: "The comb antibiotic sensitivity test" is a quick, reliable and cost effective method to determine the susceptibility of bacteria to different antibiotics. The purpose of this study is to design a plate that is easy and quick to use, and enable to be interpreted easily without the need for measurement of the margins with a ruler. Material and Methods: First, Clinical and Laboratory Standards Institute data about the maximum growth inhibitory haloes formed with antibiotics and various micro-organisms were statistically examined and determined that the most (99.7%) zone of inhibition growth is formed in the range of 42 mm. Accordingly, the obtained number (42 mm) and conventional plate size (100 mm) used for testing sensitivity were punched into Solid works software which was used to determine the best place of strip and shoulder plates. After that the efficacy this media were examined by determination of MIC Staphylococcus aureus and Klebsiella pneumonia, non-graded and graded plate shoulders were searched and compared. Results: Has been placed two combs MIC in a plate in this method and didn’t create growth inhibitory haloes interferences. Obtained MIC for Nitrofurantoin( 10 µg/ml) , Amikacin(0.5 µg/ml), Gentamicin(1 µg/ml) , and Amoxicillin (0.5 µg/ml) against S.aureus , MIC Nalidicsic Acid, Amikcin, Gentamicin and Nitrofurantoin against K.pneumonia was 0.1, 0.5, 0.5 and 10 µg/ml ,respectively. Conclusion:The comparison between this new innovative method and standard methods (Clinical Laboratory Standards Institute - CLSI) shows that there a marked reduction in the interference of antibiotic therapy and will also reduce time of interpretation. Key words: Plate, Antibiogram Comb, MIC, Antibiotics, Drug resistance.
M Hasannejad Bibalan, N Javid, M Samet, F Shakeri, Ea Ghaemi,
Volume 8, Issue 3 (8-2014)
Abstract

Abstract Background and Objective: Biofilm is a complex microbial community embedded in a self-produced extracellular polymeric matrix. We aimed to study the extent of biofilm formation by S. Areas isolates and its relation to some phenotypic and genotypic criteria. Material and Methods: One hundred-fifty strains of Staphylococcus aureus isolated from Gorgan were studied. Microtiter plate assay method was used for investigation of biofilm formation.The biofilm formation of strains were recorded and its relation to accessory gene regulator (agr) and antibiotic resistance were assessed by X2 test. Results: Eighty-four isolates (56%) were able to form biofilm. The strength of biofilm formation in agr group I was more than that of other groups. The biofilm formation among S. Areas isolated from the wound and urine (both with 75 %) had the highest capability. Methicillin-resistant isolates had a greater ability to biofilm formation. Conclusion: Methicillin resistant isolates had a greater ability to biofilm formation. Given the importance and treatment related problems of Methicillin-Resistant Staphylococcus Aureus (MRSA) especially Community Acquired-Methicillin-Resistant Staphylococcus Aureus (CA-MRSA), it is a necessity to control or remove the biofilm formation alongside antibiotic treatment. Keywords: Staphylococcus Aureus, Biofilm, Microtiter Plates Assay, PCR
M Vakili (phd), N Jomeh Pour, E Zarifi , M Baghbanian , A Dehghan , M Sahimi , L Gudarzi ,
Volume 9, Issue 3 (9-2015)
Abstract

Abstract

Background and Objective: Given that microbial contamination is the third largest cause of mortality caused blood transfusion, the examination of contamination in platelet concentrates is essential in blood transfusion centers. The purpose of this study was to achieve a rapid test for bacterial contamination of platelets concentration.

Material and Methods: This laboratory study was conducted on 14 bags of platelet concentrates prepared from Yazd Blood Transfusion Center. Six platelet bags were infected by Staphylococcus epidermidis; six by Klebsiella with a concentration of 150, 15 and 1.5, and two bags were considered as control. In specific intervals, the bags were sampled aseptically and examined by the methods including culture, gram stain, Glucose and PH measurement.

Result: Due to the presence of dextrose, the initial glucose level of platelet bags was above 300 mg/dl. The mean of  Glucose in contaminated platelet bags was progressively  decreased in  3 days in that it reached  165 mg/dl in the third day ( p = 0.002) . The level of PH had a declining process in that it averagely decreased from PH 7.3 to PH 5.2 (P=0.017(. The results of culturing and smear of the bacteria were different according to the concentrations used in the study.

Conclusion: We can detect the contamination of platelet bags by measuring the level of glucose and PH level in the least amount of time.

Keywords: Blood Platelets; Klebsiella; Staphylococcus Epidermidis.


Nahid Bijeh, Asra Askari , Saeed Ramezani, Babisan Askari,
Volume 12, Issue 1 (1-2018)
Abstract

 
Background and objectives: The aim of this study was to investigate the effect of eight weeks of aerobic exercise on serum iron, serum ferritin, platelet count, mean platelet volume, and some immunity indices in non-athlete females.
  • In this study, 30 non-athlete females aged 30-45 years were randomly divided into an experimental and a control group. The experimental group was subjected to perform aerobic exercise at 60-70% of maximal heart rate for eight weeks, three sessions per week and one hour per session. Blood parameters were measured before the exercise program and after the completion of program by taking 2 ml blood samples from the venous vein of the participants in the sitting position. Finally, t-test was used to compare the pre-test and post-test means of each group and independent t-test was used to compare the two groups at significance of 0.05.
  • : After eight weeks of aerobic exercise, there was a significant increase in mean platelet volume and a significant decrease in serum iron and ferritin levels in the experimental group (P <0.05). There was a slight decrease in the number of platelets, white blood cells, granulocytes, monocytes and lymphocytes (P<0.05).
            Conclusion: We recommend physical education instructors, athletes and non-athletes to consider iron supplementation during aerobic exercise, and modify appropriate training intensity based on the fitness and age of trainees to prevent risk of anemia.
            KEYWORDS: Aerobic exercise, platelet, iron, ferritin, white blood cell.
 

Page 1 from 1     

© 2007 All Rights Reserved | Medical Laboratory Journal

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.